Gerät zur Korrosionsanalyse Canin
Gerät zur Korrosionsanalyse Canin

Concrete, Materials, Components

CANIN+

The Canin+ corrosion analyzing instrument provides two methods for investigating and assessing the corrosion of steel in concrete:

  • Half-cell corrosion potential method - accurate field potential measurements aid in detecting active corrosion in rebars.
  • Concrete resistivity method - the instrument measures the specific electrical resistivity of concrete.

This combination of potential and resistivity measurement improves information about the corrosion condition of rebars.

In order to satisfy individual testing needs, Canin+ is available individually with a rod electrode, wheel electrode and/or Wenner probe configurations or as a complete system with all components.

Features

  • Immediate presentation of test area and reading directly on the instrument’s display
  • Up to 240 measurement values are displayed at a time in easy-to read grey-scale. A menu-driven approach facilitates the simple operation using just nine functions keys
  • Total memory for 235’000 readings which can be stored
  • The Canin ProVista Software allows downloading, presenting and editing data measured by the Canin+ half-cell instrument
  • New features such as a backlight display and faster processing of data extend the functionality of Canin+

Applications

  • Canin+ is ideally suited for the assessment of corrosion potentials on large areas of 8’000 m2 (83’000 sq.ft.) or multiples thereof. This is made possible by the selectable grid size. The wheel electrode in particular makes it easy to rapidly cover larger areas
  • The measuring principle and the factors that need to be considered by the engineer assessing the corrosion probability are described in the document "Measuring principle of Canin - Fundamentals for an optimum interpretation" which can be found in the downloads section
  • The Canin ProVista Software also provides an invaluable aid in the assessment of the corrosion probability of a structure. An example of the application of this software can be found in the download section.

Product Variations

Four variations of the Canin+ are available:

  • Canin+ configuration with rod electrode (for potential measurements only)
  • Canin+ configuration with rod and wheel Electrodes (for potential measurements only)
  • Canin+ with Wenner probe (for resistivity measurements only)
  • Canin+ combined configuration with rod and wheel electrodes and Wenner probe (for potential and resistivity measurements)

Technical Data

Potential Measurement
Measurement range±999 mV
Memory non-volatile memory for up to 235’000 measurements stored in up to 71 object files
Software Canin ProVista Software for downloading data and evaluation on PC
Battery operation six LR 6 (AA) batteries, 1.5 V for up to 60 h (or 30 h with activated backlight)
Resistance Measurement
Measurement range 0 bis 99 kOcm
Resolution 1 kΩcm
Memory non-volatile memory for up to 5’800 measurements stored in up to 24 object files
Data transfer by Windows Hyperterminal
Battery operation six LR 6 (AA) batteries, 1.5 V for up to 40 h (or 20 h with activated backlight)
General
Impedance 10 MΩ
Operating temperature 0 bis 60 °C
Storage temperature -10 bis 60 °C
Display 128 x 128 pixel graphic LCD with backlight
Data output RS 232 interface, USB with adapter
Case dimensions 580 x 480 x 210 mm (22,8 x 18,9 x 8,3 in)
Weight net. 10.6 kg (23.5 lbs); shipping 14 kg (31.1 lbs)

SUSPA-DSI Webshop

Item-No.

Description

Price/pcs

Basket
33000201 CANIN+ Corrosion Analysing Instrument with 1 bar electrode 3350,00 €
33000205 CANIN Corrosion Analysing Instrument with bar electrode and wheel electrode 6075,00 €
33000206 CANIN+ Corrosion Analysing Instrument with bar electrode, wheel electrode and Wennersonde 7395,00 €
33000203 CANIN Corrosion Analysing Instrument with Wennersonde 3725,00 €

Data Sheet CANIN

Do you have further questions? Please contact us.

CANIN - Corrosion Analysing Instrument
Filetype: pdf
Filesize:425 kB
Published: 01.06.2008